-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Bob Shannon
Sent: Sunday, August 10, 2014 12:53
To: [email protected]
Subject: Re: Extents more than One for load modules library

> Load libraries go to more than one extent all the time. I don't believe there 
> is any "general" problem.

The problem occurs if the libraries are in the Linklist. A new extent won't be 
reflected in the DEB. For non-Linklist libraries it shouldn't be a problem 
until the next IPL or until a new Linklist Set is created..

Bob Shannon
Rocket Software
================================

This problem is not limited to linklist libraries, but applies to all open 
libraries. E.g. if your IMS or CICS loadlib has extents and takes one more, 
also this is not reflected in the DEB and modules there cannot be found.

Kees.


********************************************************
For information, services and offers, please visit our web site: 
http://www.klm.com. This e-mail and any attachment may contain confidential and 
privileged material intended for the addressee only. If you are not the 
addressee, you are notified that no part of the e-mail or any attachment may be 
disclosed, copied or distributed, and that any other action related to this 
e-mail or attachment is strictly prohibited, and may be unlawful. If you have 
received this e-mail by error, please notify the sender immediately by return 
e-mail, and delete this message. 

Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its 
employees shall not be liable for the incorrect or incomplete transmission of 
this e-mail or any attachments, nor responsible for any delay in receipt. 
Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal Dutch 
Airlines) is registered in Amstelveen, The Netherlands, with registered number 
33014286
********************************************************
                        


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to