Thank you both!
On Tue, Aug 26, 2014 at 7:43 AM, John McKown <[email protected]> wrote: > On Tue, Aug 26, 2014 at 6:35 AM, Mark Pace <[email protected]> wrote: > > I want to add a couple of parameters to my usual LOCSITE command, except > > now it will be longer than 72 characters. Looking at the manual it > doesn't > > say if there is a way to make a continuation or if you can use multiple > > LOCSITE commands. Anyone know the correct way to do this? > > > > -- > > > > Mark D Pace > > LOCSITE command are accumulative. If you set a parameter multiple > times, the last value set is the one used thereafter. I have often > used multiple. > > e.g. > > LOCSITE LRECL=80 > LOCSITE RECFM=FB > LOCSITE UNIT=SYSDA > > and > > LOCSITE LRECL=80,RECFM=FB,UNIT=SYSDA > > have the same effect . > > -- > There is nothing more pleasant than traveling and meeting new people! > Genghis Khan > > Maranatha! <>< > John McKown > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > -- The postings on this site are my own and don’t necessarily represent Mainline’s positions or opinions Mark D Pace Senior Systems Engineer Mainline Information Systems ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN