Thank you both!

On Tue, Aug 26, 2014 at 7:43 AM, John McKown <[email protected]>
wrote:

> On Tue, Aug 26, 2014 at 6:35 AM, Mark Pace <[email protected]> wrote:
> > I want to add a couple of parameters to my usual LOCSITE command, except
> > now it will be longer than 72 characters.  Looking at the manual it
> doesn't
> > say if there is a way to make a continuation or if you can use multiple
> > LOCSITE commands.  Anyone know the correct way to do this?
> >
> > --
> >
> > Mark D Pace
>
> LOCSITE command are accumulative. If you set a parameter multiple
> times, the last value set is the one used thereafter. I have often
> used multiple.
>
> e.g.
>
> LOCSITE LRECL=80
> LOCSITE RECFM=FB
> LOCSITE UNIT=SYSDA
>
> and
>
> LOCSITE LRECL=80,RECFM=FB,UNIT=SYSDA
>
> have the same effect .
>
> --
> There is nothing more pleasant than traveling and meeting new people!
> Genghis Khan
>
> Maranatha! <><
> John McKown
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>



-- 
The postings on this site are my own and don’t necessarily represent
Mainline’s positions or opinions

Mark D Pace
Senior Systems Engineer
Mainline Information Systems

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN