I would think you could call BPX1ATM (attach_execmvs()) from COBOL. 

In article <CAHm_n2k3Y6YPjiF30BFYBhqFhvSgo0dub2wdVNne2K=tl8b...@mail.gmail.com> 
you wrote:
> We have a batch utility program that is built in C that uses the XPLINK
> version of the C runtime.    A customer would like to "dynamically" call
> this from COBOL, but of course the LE runtimes are not compatible:

> IGZ0179S A dynamic call to COZBATCH failed because the load module contains
> one
>  or more routines with XPLINK linkage.


> Is it possible to do the equivalent of a Assembler "LINK" (separate RB and
> LE runtime environment) from COBOL without writing an Assembler stub
> routine?

> Thanks,

> Kirk Wolf
> Dovetailed Technologies
> http://dovetail.com

-- 
Don Poitras - SAS Development  -  SAS Institute Inc. - SAS Campus Drive
[email protected]           (919) 531-5637                Cary, NC 27513

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to