Hi Varun,

have you tried to refer back to the dataset name? I have a similar JCL 
with the output vol specified like this (on the second and subsequent 
steps):

//TAPE2    DD DSN=CIMSSP.TAPE3592.BACKUP.RSDV02,
//         UNIT=3592ATLC,DISP=(,CATLG),LABEL=(2,SL),
//         RETPD=1,VOL=(,RETAIN,REF=CIMSSP.TAPE3592.BACKUP.RSDV01)

Regards,
Edgard 


IBM Mainframe Discussion List <[email protected]> gravou em 
25/09/2014 09:36:23:

> De: Mainframe Sysprog <[email protected]>
> Para: [email protected]
> Data: 25/09/2014 09:36
> Assunto: Refer Back in JCL
> Enviado por: IBM Mainframe Discussion List <[email protected]>
> 
> Hi All,
> 
> I have been trying the REFER Back statement in JCL to take multiple 
backups
> on a 3592 tape using a JCL such as below. However, for some reason this
> doesn't seem to be working.
> 
> //STEP1    EXEC PGM=ADRDSSU
> //SYSPRINT DD SYSOUT=*
> //DASD1    DD UNIT=3390,VOL=SER=RSDV01,DISP=SHR
> //TAPE1    DD DSN=CIMSSP.TAPE3592.BACKUP.RSDV01,
> //         UNIT=3592ATLC,DISP=(NEW,CATLG),LABEL=(1,SL),
> //         RETPD=1,VOL=(,RETAIN)
> //SYSIN    DD *
>   DUMP IDD(DASD1) ODD(TAPE) -
>      DATASET(INCLUDE(**))
> /*
> //STEP2    EXEC PGM=ADRDSSU
> //SYSPRINT DD SYSOUT=*
> //DASD2    DD UNIT=3390,VOL=SER=RSDV02,DISP=SHR
> //TAPE2    DD DSN=CIMSSP.TAPE3592.BACKUP.RSDV02,
> //         UNIT=3592ATLC,DISP=(,CATLG),LABEL=(2,SL),
> //         RETPD=1,VOL=(,RETAIN,REF=*.STEP1.TAPE1)
> //SYSIN    DD *
>   DUMP IDD(DASD1) ODD(TAPE) -
>      DATASET(INCLUDE(**))
> 
> I keep getting an error such as :
> 
> IGD306I UNEXPECTED ERROR DURING CBRXLCS PROCESSING  326
> RETURN CODE 12 REASON CODE 67
> THE MODULE THAT DETECTED THE ERROR IS IGDIDMUS
> SMS MODULE TRACE BACK - IDMUS IDMSU IDM00 SSIRT
> SYMPTOM RECORD CREATED, PROBLEM ID IS IGD00148
> 
> The backups work fine if I try only one backup at a time.
> 
> Does anybody see any errors with my JCL or have any suggestions on what
> should I look at?
> 
> Thanks
> Varun
> 


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to