I forgot to add IDCAMS output for this
IDCAMS SYSTEM SERVICES TIME:
23:11:16
/* IDCAMS COMMAND */
LISTCAT ENTRIES(SYS1.IODF11.WORK) -
ALL
DATA ---------- SYS1.IODF11.WORK
IN-CAT ---SYS1.MASTER.CATALOG
HISTORY
DATASET-OWNER-----(NULL) CREATION--------2014.267
RELEASE----------------2 EXPIRATION------0000.000
ACCOUNT-INFO-----------------------------------(NULL)
PROTECTION-PSWD-----(NULL) RACF----------------(NO)
ASSOCIATIONS
CLUSTER--SYS1.IODF11.WORK.CLUSTER
ATTRIBUTES
On Mon, Sep 29, 2014 at 10:34 AM, venkat kulkarni <
[email protected]> wrote:
> Hello Group,
> By mistake somebody from our team run below Job,
> which has cataloged SYS1.IODF11.WORK file into master catalog as user
> catalog.
>
> //IMPCONET JOB 'VENKAT',CLASS=A,MSGCLASS=A,NOTIFY=&SYSUID
> //IMPORT EXEC PGM=IDCAMS
> //SYSPRINT DD SYSOUT=*
> //SYSIN DD *
> IMPORT -
> CONNECT -
> OBJECTS((SYS1.IODF11.WORK -
> VOLUMES(WORK01) -
> DEVT(3390))) -
> CATALOG(SYS1.MASTER.CATALOG)
>
> But, to isolate this issue, I run below Job to disconnect this
> SYS1.IODF11.WORK file from
> the master catalog.
>
> //IMPDISCT JOB 'VENKAT',CLASS=A,MSGCLASS=A,NOTIFY=&SYSUID
> //STEP1 EXEC PGM=IDCAMS
> //SYSPRINT DD SYSOUT=*
> //SYSIN DD *
> EXPORT -
> SYS1.IODF11.WORK -
> DISCONNECT -
> CATALOG(SYS1.MASTER.CATALOG)
>
> But I encountered below error
>
> IDCAMS SYSTEM SERVICES TIME:
>
> EXPORT -
> SYS1.IODF11.WORK -
> DISCONNECT -
> CATALOG(SYS1.MASTER.CATALOG)
> IDC3014I CATALOG ERROR
> IDC3009I ** VSAM CATALOG RETURN CODE IS 10 - REASON CODE IS IGG0CLFK-14
> IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12
>
> IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 12
>
>
> I looked into RETURN code 10 and reason code 14
>
> *14**Explanation:* On a disconnect request, the connector record was
> missing or incorrect.
>
>
> Any clue to resolve this issue.
>
>
>
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN