Let me rephrase my statement a little

Depending on how hard you worked at creating an issue with VSAM, It can be that 
much more difficult to fix it.  IBM has tools and expertise with their product. 
 You might find a solution with them.

My thought would be to copy the VSAM IODF dataset to a new IODF dataset.  

Then work gently to delete the original one.



Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Lizette Koehler
> Sent: Monday, September 29, 2014 7:25 AM
> To: [email protected]
> Subject: Re: IODF catalog issue
> 
> You might want to go to IBM for assistance.
> 
> They may be able to help you fix your issue.
> 
> VSAM can be difficult in fixing issues depending on how hard you worked to 
> create
> an issue.
> 
> Lizette
> 
> 
> 
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of venkat kulkarni
> > Sent: Sunday, September 28, 2014 10:04 PM
> > To: [email protected]
> > Subject: IODF catalog issue
> >
> > Hello Group,
> >                      By mistake somebody from our team run below Job,
> > which has cataloged SYS1.IODF11.WORK file into master catalog as user
> catalog.
> >
> > //IMPCONET JOB 'VENKAT',CLASS=A,MSGCLASS=A,NOTIFY=&SYSUID
> > //IMPORT EXEC PGM=IDCAMS
> > //SYSPRINT DD SYSOUT=*
> > //SYSIN  DD *
> >  IMPORT -
> >  CONNECT -
> >    OBJECTS((SYS1.IODF11.WORK -
> >    VOLUMES(WORK01) -
> >    DEVT(3390))) -
> >  CATALOG(SYS1.MASTER.CATALOG)
> >
> > But, to isolate this issue, I run below Job to disconnect this
> > SYS1.IODF11.WORK file from the master catalog.
> >
> > //IMPDISCT JOB 'VENKAT',CLASS=A,MSGCLASS=A,NOTIFY=&SYSUID
> > //STEP1 EXEC PGM=IDCAMS
> > //SYSPRINT DD SYSOUT=*
> > //SYSIN DD *
> >      EXPORT -
> >            SYS1.IODF11.WORK -
> >            DISCONNECT -
> >            CATALOG(SYS1.MASTER.CATALOG)
> >
> > But I encountered below error
> >
> > IDCAMS  SYSTEM SERVICES                                           TIME:
> >
> >      EXPORT -
> >            SYS1.IODF11.WORK -
> >            DISCONNECT -
> >            CATALOG(SYS1.MASTER.CATALOG) IDC3014I CATALOG ERROR
> > IDC3009I ** VSAM CATALOG RETURN CODE IS 10 - REASON CODE IS
> > IGG0CLFK-14 IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12
> >
> > IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION
> CODE WAS 12
> >
> >
> > I looked into RETURN code 10 and reason code 14
> >
> > *14**Explanation:* On a disconnect request, the connector record was
> > missing or incorrect.
> >
> >
> > Any clue to resolve this issue.
> 

----------------------------------------------------------------------