It appears that we captured relevant problem data via GTF tonight, so "we shall
see what we shall see, when we see it".
-jc-
> -----Original Message-----
> From: Chase, John
> Sent: Thursday, October 09, 2014 12:44 PM
> To: 'IBM Mainframe Discussion List'
> Subject: RE: Upgrade to Enterprise COBOL v5.1
>
> > -----Original Message-----
> > From: IBM Mainframe Discussion List On Behalf Of Keith Smith
> >
> > Cut-n-past to the list maybe?
>
> I s'pose:
>
> "something like
> SLIP
> SET,SA,RA=(25DCC,25DCF),ASIDSA=('JOBNA*'),A=TRACE,TD=(STD,REGS,25DCC,25DCF
> ),ID=OVLY,END"
>
> And "I would go with a MODE=INT GTF trace, with SD=10M.
> The SLIP dump of the U4087 abend should contain the most recent 10MB of GTF
> trace."
>
> The specific addresses in the SLIP are where the job has allocated the
> storage that holds the pointer
> that got corrupted in each previous dump, so we're "gambling" on it being at
> the same virtual address
> in each job next time we try to trap the corrupter. Note the generic job
> name in ASIDSA.
>
> -jc-
>
> >
> > On Thu, Oct 9, 2014 at 11:00 AM, Chase, John <[email protected]> wrote:
> >
> > > > -----Original Message-----
> > > > From: IBM Mainframe Discussion List On Behalf Of Jim Mulder
> > > >
> > > > > [ snip ]
> > > >
> > > > I reviewed your PMR and dumps, and made some suggestions in the PMR.
> > > >
> > > > Jim Mulder z/OS System Test IBM Corp. Poughkeepsie, NY
> > >
> > > Thank you, Sir. We'll run it by Change Control, and possibly try
> > > your suggestions tonight.
> > >
> > > -jc-
> > >
> > > ********************************************************************
> > > ** Information contained in this e-mail message and in any
> > > attachments thereto is confidential. If you are not the intended
> > > recipient, please destroy this message, delete any copies held on
> > > your systems, notify the sender immediately, and refrain from using
> > > or disclosing all or any part of its content to any other person.
> > >
> > > --------------------------------------------------------------------
> > > -- For IBM-MAIN subscribe / signoff / archive access instructions,
> > > send email to [email protected] with the message: INFO
> > > IBM-MAIN
> > >
> >
> >
> >
> > --
> > Keith Smith
> > Engineer-Enterprise Sys Sr.-IT Capacity & Performance Shaw Industries Inc.
> > Subsidiary of Berkshire Hathaway
> > 616 E Walnut Ave
> > Mail Drop 072-04
> > Dalton, GA 30721
> > Email: [email protected] Office: 706.532.3244
> >
> > Please consider the environment before printing.
> >
> > --
> > **********************************************************
> > Privileged and/or confidential information may be contained in this
> > message. If you are not the addressee indicated in this message (or
> > are not responsible for delivery of this message to that
> > person) , you may not copy or deliver this message to anyone. In such
> > case, you should destroy this message and notify the sender by reply e-mail.
> > If you or your employer do not consent to Internet e-mail for messages
> > of this kind, please advise the sender.
> > Shaw Industries does not provide or endorse any opinions, conclusions
> > or other information in this message that do not relate to the official
> > business of the company or
> its subsidiaries.
> > **********************************************************
> >
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> > email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN