On Mon, 3 Nov 2014 12:16:49 -0500, Denis Gäbler wrote:

you can do that very easily, with pragma convert in z/OS and z/VM:
 
http://www-01.ibm.com/support/knowledgecenter/SSB27U_6.2.0/com.ibm.zos.r12.cbclx01/zos_pragma_convert.htm
  
Or, equivalently:

    
http://pic.dhe.ibm.com/infocenter/zos/v2r1/topic/com.ibm.zos.v2r1.cbclx01/zos_pragma_convert.htm

... where I read:

    The following are not converted:

        A string or character constant specified in hexadecimal or octal escape 
sequence format
        (because it represents the value of the desired character on output).

That could be an adverse design choice.  For example in ported source
code if the programmer has specified 0xA0, the intent was more likely
  than the EBCDIC 0xA0 code point.

-- gil

----------------------------------------------------------------------