<snip>
GET "12345678910/PROD/GIMPAF.XML" "/xxxxxx/xxxxxx/xxxxxx/xxxxxxxxx/GIMPAF.XML"
  (REPLACE
EZA1701I >>> TYPE I
200 Type set to I.
EZA1460I Command:
EZA1701I >>> PORT      nn,n,nn,n,nn,nnn
EZA2589E Connection to server interrupted or timed out. Waiting for reply
EZA1721W Server not responding, closing connection.
EZA1636I *** I can't open a data-transfer connection:
EZA1735I Std Return Code = 16000, Error Code = 00009

You were able to make a secure connection, so that's a good thing. However, I'm thinking you have a firewall getting in the way of the data connection. As already suggested, try using passive mode (EPSV4 TRUE). If you still have trouble, you may have to get help from Comm Server Level 2 to study an IP trace.

Kurt Quackenbush -- IBM, SMP/E Development

----------------------------------------------------------------------