On Mon, Apr 20, 2015 at 9:13 AM, Steff Gladstone <[email protected]> wrote:
> How do I use the ISGENQ macro in such a way that the ENQ lasts for the life > of the entire job (or several job steps) and not just for the life of a > single job-step? Would specifying the TCB address of the initiator TCB on > the TCB parameter work? Any better ideas? > > Thanks, > Steff Gladstone > I don't know that there is a _reliable_ way to do this. If you were to direct the ENQ to reside on the initiator's TCB, I am fairly sure that the ENQ would not go away at the end of your job because the initiator TCB does not terminate at end of job. I admit to being a bit curious as to why you need this, if you are allowed to say. -- If you sent twitter messages while exploring, are you on a textpedition? He's about as useful as a wax frying pan. 10 to the 12th power microphones = 1 Megaphone Maranatha! <>< John McKown ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN