   at 05:13 PM, Steff Gladstone <[email protected]> said:

>How do I use the ISGENQ macro in such a way that the ENQ lasts for
>the life of the entire job (or several job steps) and not just for
>the life of a single job-step?

Cautiously and with trepidation.

>Would specifying the TCB address of the initiator TCB on the TCB
>parameter work? 

That depends on your definition of work. It will do what you expect
most of the time and will provide some excitement when it doesn't.

>Any better ideas?

Allocaring a data set with DISP=(OLD,PASS) would be a lot safer.

-- 
     Shmuel (Seymour J.) Metz, SysProg and JOAT
     ISO position; see <http://patriot.net/~shmuel/resume/brief.html> 
We don't care. We don't have to care, we're Congress.