I am not sure you have provided enough detail here.  We finished our upgrade to 
z/OS V2.1 and did not see this issue.

Could you post the entire Summary dump from the JOBLOG with Registers?
Could you post additional message in SYSLOG around where the S0C4 occurs?
What are you running when you get this error?
I would guess that this ran successfully prior to z/OS V2.1.  Did you make any 
changes before moving this to z/OS V2.1?  Or is this the exact same process 
that runs successfully on your down leveled LPAR?


Lizette


-----Original Message-----
>From: John Norgauer <[email protected]>
>Sent: Jun 2, 2015 11:16 AM
>To: [email protected]
>Subject: intermittant abends
>
>We are close to turning on 2.1 z/os on in our production LPAR.
>
>We are getting sporadic abends of this kind:
>
>IEC999I IFG0554P,SYSJCNTE,S1
>IEA995I SYMPTOM DUMP OUTPUT  688
>SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
>
>It appears when I display user info from RACF.
>When I ran a terse batch job, it appeared.
>
>I sent a dump to IBM and have not heard back so that's why I posted to the 
>list.
>
>Any thoughts from the list?
>

----------------------------------------------------------------------