I'm with Tom. Since the advent of IODF in the 90s, we have always given each plex (sys- or mono-) its own copy of the IODF. Although not required, we catalog it in master. If nothing else, you have backups in case one get marfed or accidentally deleted.
SAMPLIB contains sample jobs to migrate an IODF. Look at members CBDS* . Simply submit a job on the system where you manage HCD. Job1 offloads and transmits IODF to another system over NJE, where Job2 unloads and catalogs IODF on target system. It really is pretty fast and very reliable. . . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 626-302-7535 Office 323-715-0595 Mobile jo.skip.robin...@sce.com -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Thomas Conley Sent: Thursday, June 11, 2015 9:57 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Share IODF in different sysplex same CPC On 6/11/2015 11:34 AM, Jorge Garcia wrote: > Hello John and Mary: > > Our requirements are (if it's possible). Updates in one and only IODF and > then transmit it to another systems. With this option we avoid updates in two > o more IODF and we save the IODF integrity. > The share user catalog option is the fast and easy way for dynamic activation > in all systems, but It's dangerous if you aren't careful. > > This should be the GRSRNLxx configuration with this option: > > RNLDEF RNL(EXCL) TYPE(GENERIC) QNAME(SYSDSN) RNAME(hlq iodf) RNLDEF > RNL(EXCL) TYPE(GENERIC) QNAME(SYSZVVDS) RNAME(SD) RNLDEF RNL(EXCL) > TYPE(GENERIC) QNAME(SYSVTOC) RNAME(volser catalog device) RNLDEF RNL(EXCL) > TYPE(SPECIFIC) QNAME(SYSIGGV2) > RNAME('iodf user catalog ') > RNLDEF RNL(EXCL) TYPE(PATTERN) QNAME(SYSIGGV2) > RNAME('????????????????????????????????????????????iodf user catalog > ') > > > The IODF SYS1 option and Mary option I think that it's the same. With the > Mary option you avoid DEFINE and REPRO executions. The transmit and receive > option is faster. Mary I understand that you have cataloged the same iodf HLQ > in differerents user catalogs in different systems? With the same HLQ like > IOCDS you should execute a right dynamic activacion, Is It true? > Jorge, This is dangerous and unnecessary. You can catalog the IODF on each separate system in the master catalog, or a user catalog shared among systems IN THE SAME SYSPLEX. You shouldn't be sharing a user catalog cross-sysplex. I used to propagate IODF's with DFDSS DUMP, FTP, RESTORE, but that failed once after working for over a year. So now I use the HCD EXPORT and IMPORT functions, which while slower, is guaranteed to work. Regards, Tom Conley ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN