> Take a look at how WAS does it

Not the best way to do a one-byte literal compare LOL!

CLC   SM120RTY,=AL1(SM120VAL)    SMF RECORD 120 ?              
BNE   LEAVE0                     NO, RETURN          

Charles
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of David Crayford
Sent: Tuesday, June 16, 2015 4:29 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Is there any tools or interface which could analyse or monitor 
SYS1.MANX directly?

Real time SMF data capture is non-trivial and normally requires cross-memory 
services. Take a look at how WAS does it to get an idea 
http://www.ibm.com/developerworks/tivoli/library/t-wasz-smf/. If you're using 
SMF logstreams it may be easier. But it looks like your using MAN 

----------------------------------------------------------------------