On Sun, 12 Jul 2015 17:34:41 -0400, Scott Ford <[email protected]> wrote:

>No sir, its subpool=231, linkage=system, thus supervisor state required
>

From Authorized Assembler Services description of the STORAGE macro:
http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/iea2a4b1/11.1.1?SHELF=all13be9&DT=20120813104512&CASE=
 
or http://preview.tinyurl.com/o3ca8au
<quote>
           
Environment: The requirements for the caller are:
 ...                                             
For LINKAGE=SYSTEM or LINKAGE=SVC: for all other         
subpools [Walt: that is, for subpools except 0-127, 131, or 132], one or more 
of the following:                  
                                                          
 °   Supervisor state                                     
 °   PSW key 0-7                                          
 °   APF-authorization.
</quote>

-- 
Walt

----------------------------------------------------------------------