IBM Mainframe Discussion List <[email protected]> wrote on 07/12/2015 09:40:25 PM:
> From: Walt Farrell <[email protected]> > To: [email protected] > Date: 07/12/2015 11:08 PM > Subject: Re: SYSTEM KEY Programming Was: IVSK and SPKA > Sent by: IBM Mainframe Discussion List <[email protected]> > > On Sun, 12 Jul 2015 17:34:41 -0400, Scott Ford <[email protected]> wrote: > > >No sir, its subpool=231, linkage=system, thus supervisor state required > > > > From Authorized Assembler Services description of the STORAGE macro: > http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/iea2a4b1/ > 11.1.1?SHELF=all13be9&DT=20120813104512&CASE= > or http://preview.tinyurl.com/o3ca8au > <quote> > > Environment: The requirements for the caller are: > ... > For LINKAGE=SYSTEM or LINKAGE=SVC: for all other > subpools [Walt: that is, for subpools except 0-127, 131, or 132], > one or more of the following: > > ° Supervisor state > ° PSW key 0-7 > ° APF-authorization. > </quote> > > -- > Walt APF-authorization checking was added for STORAGE with LINKAGE=SYSTEM in z/OS 1.10. Jim Mulder z/OS System Test IBM Corp. Poughkeepsie, NY ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN