In <[email protected]>, on
07/17/2015
at 04:42 PM, Roland Kinsman <[email protected]> said:
>Which seems to suggest that PDSE cannot be allocated on VIO.
4.4.6 Allocation of Virtual I/O
You cannot use VIO for permanent data sets, VSAM data sets, or
partitioned data sets extended (PDSEs).
>So why does it work on one LPAR but not the other?
Because one is VIO and the other is not.
Code a UNIT parameter for non-SMS-managed data sets. UNIT
must specify a VIO unit name. During system initialization
the installation must define new and/or existing unit names
as VIO; the installation should maintain a list of the VIO
unit names.
--
Shmuel (Seymour J.) Metz, SysProg and JOAT
ISO position; see <http://patriot.net/~shmuel/resume/brief.html>
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN