Yep, doing a RECEIVE for a ++RELEASE HOLDDATA does not do anthing. Before:
Entry Type: HOLDDATA Zone Name: GLOBAL
Entry Name: SZPE113 Zone Type: GLOBAL
HOLD DATA
----------------------------------------------------------------------
++HOLD(SZPE113) SYSTEM REASON(ACTION) FMID(PKZ1500) .
++HOLD(SZPE113) SYSTEM REASON(PSTINST) FMID(PKZ1500) DATE(15258) .
******************************* Bottom of data ***********************
JCL:
//PROCESS EXEC SMPECC,RGN=512
//SMPHOLD DD *
++RELEASE(SZPE113) SYSTEM REASON(ACTION) FMID(PKZ1500) .
//SYSIN DD *
SET BDY(GLOBAL) .
RECEIVE
HOLDDATA
LIST
.
/*
Result:
RECEIVE ++HOLD/++RELEASE SUMMARY REPORT
NOTE: SMD NF - SYSMOD NOT RELEASED - NOT FOUND IN
THE GLOBAL ZONE
RSN NF - SYSMOD NOT RELEASED - NOT HELD FOR
THIS REASONID
INT HLD - SYSMOD NOT RELEASED - CANNOT
RELEASE INTERNAL SYS HOLD
SYSMOD TYPE STATUS REASON FMID ++HOLD MCS
STATEMENTS
SZPE113 SYS RSN NF ACTION PKZ1500
*********************************************************************** Bottom
of Data ***************
Suppose I will have to open a PMR.
Thanks
Bruce
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN