I hate smart phones sometimes.
1) List datasets from volume(408922)
2) Try to recall all valid datasets
3) Recycle empty tape

Note: z/OS V2.1 will let you have up to 255 connected volumes

Lizette
 

-----Original Message-----
>From: Lizette Koehler <[email protected]>
>Sent: Sep 15, 2015 9:58 AM
>To: [email protected]
>Subject: Re: HSM Error Message
>
>1. list datasets form volume(832303)
>2. try to recall all valid datasets
>3. recycle empty tape
>
>
>Lizette
>
>-----Original Message-----
>>From: "Steely, Mark" <[email protected]>
>>Sent: Sep 15, 2015 8:15 AM
>>To: [email protected]
>>Subject: HSM Error Message
>>
>>I am getting the following message trying to recycle a volume:
>>
>>ARC0445I VOLUME 408922 CANNOT BE RECYCLED, REASON= 0028, EXPLANATION: 
>>CONNECTED SET TOO LONG
>>
>>Reason 28:
>>
>>28        CONNECTED SET TOO LONG: DFSMShsm will not recycle connected sets
>>          exceeding 40 volumes. The volume specified belongs to a
>>          connected set exceeding this limit.
>>
>>These are spill volumes. What can I do to fix this ?
>>
>>The list with DSI options displayed 100's of files on these tapes.
>>
>>We are z/os v1r13.
>>
>>Any help would be appreciated.
>>
>>Thanks
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to