I have an HMC running 2.10.2 version on a Unix box.  It works just fine
from its attached console, but refuses access from our local LAN.
Basically attempts to connect to it just wait and time out.
- HMC on a "10" network
- I can Ping it fine, and the DNS name, and the DNS name resolves properly
- Cannot telnet, or make other type of connection
- I confirmed with my network folk that the ports in the 2.10.2 HMC manual
Appendix c were open, and he stated that not only were they open, but there
is no firewall inside this local net.
- I confirmed that
Hardware Management Console Settings
Customize Console Services
Remote Operation is ENABLED
- I confirmed that my UID had Remote Web access enabled, even tho I am not
even getting to the login screen.
    So everything I have been able to research appears in order, but I am
still unable to connect. Any suggestions where to look here?

----------------------------------------------------------------------