Put monitors in SYSSTC. This gives them the second highest DP in the system. You cannot completely control the DP in Service Classes.
- -teD - Original Message From: phil yogendran Sent: Thursday, November 26, 2015 11:02 To: [email protected] Reply To: IBM Mainframe Discussion List Subject: WLM and Dispatching Priority Hello All, I need some assistance with being able to get a proper DP assigned to a set of tasks. The problem is this; I have 2 tasks, SYSVIEW and CICSLOGR and many CICS tasks. CICSLOGR is a subtask attached by SYSVIEW. In WLM, SYSVIEW is set to a service class of 'monitor' with an importance of 1 and velocity of 75. The CICS regions are set to a service class of 'CICSA' which has an importance of 1 and velocity goal of 65. However, what I see is that the CICS regions run at a DP of F6 and SYSVIEW is at F4. How can I make sure that SYSVIEW and CICSLOGR run at a higher DP? I'm on z/OS 1.13 and in a sysplex environment. Looking forward to your response. Thanks. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN