On Tue, 23 Feb 2016 11:57:20 +0000, Mehrshad Manshadi  wrote:

>Hi,
>I am trying to apply UI15763 PTF on DB2 10 ( z/OS 1.12 ).
>
>The following error is appeared :
>GIM23901E ** LINK-EDIT PROCESSING FOR SYSMOD UI12617 FAILED FOR MODULE DSNHAPLY
>IN LMOD DSNHPC IN THE SDSNLOAD LIBRARY. THE RETURN CODE (04)
>EXCEEDED THE ALLOWABLE VALUE. DATE 16.054 - TIME 14:53:18 -
>SEQUENCE NUMBER 000016.
>
>Which the SEQUENCE NUMBER 000016 is as follows :
>22I 1220 27 NAME DSNHPC(R) MAX ACCEPTABLE RC=00
>54W 9203 SYMBOL SEQEXDFT UNRESOLVED. NO AUTOCALL (NCAL) SPECIFIED.
>
>My problem is that I do not know what is SYMBOL SEQEXDFT ?
> 
It probably should be a label defined as EXTRN in a ++MOD element.

>Would you please help me to solve this problem?
>
Did UI12617 or another recent PTF deliver JCLIN for DSNHPC, but not deliver
a ++MOD element that resolves SEQEXDFT?

Happens to us regularly in development.  We try not to let it escape to field.

-- gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN