On Fri, 17 Jun 2016 08:59:17 -0700, Lizette Koehler <[email protected]> 
wrote:

>After the discussion this week on recovering a PDS after IEBGENER was used
>without a member on SYSUT2, I went ahead and opened the following RFE (I did 
>not
>find any currently in RFE on this)
>
>If you like it, please vote for it
>
>It is asking IBM to put a test into IEBGENER to see if SYSUT2 is a PDS or PDSE.
>And if it is, and no member is specified on the SYSUT2, to terminate the step
>with an RC12 and message about a PDS and no member name supplied.
>
>http://www.ibm.com/developerworks/rfe/execute?use_case=viewRfe&CR_ID=90179

I thought the most recent problem we discussed was that a member name was 
specified, but the DCB parameters were incorrect, causing issues accessing the 
older members after the new member was created?

-- 
Walt

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN