Oh, how I wish that was true. Tried many of the suggestions posted both before 
and after I submitted the problem. Iebgener to different size pds`s 80 & 124. 
Today, Printds looked good but same results. Xmit/receive today really made me 
hopeful but alas the output file still remained with io errors. Last week used 
z/os ditto disk browse to copy one important member, so the data still exists 
on the hardware. Just the control info is corrupted.

Sent from my LG Mobile

------ Original message------
From: Jesse 1 Robinson
Date: Sun, Jun 19, 2016 19:16
To: [email protected];
Cc:
Subject:Re: RFE opened on IEBGENER and PDS Corruption

The reason I ask about member name is that having one in the IDCAMS JCL should 
have preserved the PDS directory. This means that old data should still be 
intact. Only the oddball SYSPRINT member should be unusable once the externa 
DCB attributes are restored to FB-80. In fact it can be deleted without harming 
the other data.

Confession: I have not actually tried any of this.

.
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-302-7535 Office
[email protected]


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of ????? ?????????
Sent: Sunday, June 19, 2016 8:42 AM
To: [email protected]
Subject: (External):Re: [EXTERNAL] RFE opened on IEBGENER and PDS Corruption

Yes - definitely - but I think I went wrong when I edited the output .

.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Jesse 1 Robinson
Sent: Sunday, June 19, 2016 6:35 PM
To: [email protected]
Subject: Re: [EXTERNAL] RFE opened on IEBGENER and PDS Corruption

Please answer one burning question. When SYSPRINT went to the PDS, was a member 
name specified?

.
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-302-7535 Office
[email protected]

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of ????? ?????????
Sent: Sunday, June 19, 2016 2:31 AM
To: [email protected]
Subject: (External):Re: [EXTERNAL] RFE opened on IEBGENER and PDS Corruption

Thanks so much Lizette and Lionel.  In my case, it was SYSPRINT of IDCAMS that 
'reconfigured' the PDS file, followed by edit of the sysprint output members. 
Believe me , the 'sandbox' is now backed up daily.

.
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Lizette Koehler
Sent: Friday, June 17, 2016 7:05 PM
To: [email protected]
Subject: Re: [EXTERNAL] RFE opened on IEBGENER and PDS Corruption

Cool.

I will see if I can append to the RFE.

Lizette

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of Dyck, Lionel B. (TRA)
> Sent: Friday, June 17, 2016 9:02 AM
> To: [email protected]
> Subject: Re: [EXTERNAL] RFE opened on IEBGENER and PDS Corruption
>
> I like the idea of the RFE but could I suggest broadening it to all
> BSAM/QSAM since any program that writes output could do the same
> thing.  Put the test in the access method to prevent writing a
> sequential dataset on top of a partitioned dataset.
>
> ----------------------------------------------------------------------
> ----
> Lionel B. Dyck (TRA Contractor)
> Mainframe Systems Programmer
> Enterprise Infrastructure Support (Station 200) (005OP6.3.10) VA OI&T
> Service Delivery & Engineering
>
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of Lizette Koehler
> Sent: Friday, June 17, 2016 10:59 AM
> To: [email protected]
> Subject: [EXTERNAL] RFE opened on IEBGENER and PDS Corruption
>
> After the discussion this week on recovering a PDS after IEBGENER was
> used without a member on SYSUT2, I went ahead and opened the following
> RFE (I did not find any currently in RFE on this)
>
> If you like it, please vote for it
>
> It is asking IBM to put a test into IEBGENER to see if SYSUT2 is a PDS
> or PDSE.
> And if it is, and no member is specified on the SYSUT2, to terminate
> the step with an RC12 and message about a PDS and no member name supplied.
>
> http://www.ibm.com/developerworks/rfe/execute?use_case=viewRfe&CR_ID=9
> 0179
>
>
> Lizette Koehler
> statistics: A precise and logical method for stating a half-truth
> inaccurately

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to