> I'm not asking for help to solve that actual problem that 
> application has had and which caused the dump. I'm looking for help 
> to undestand why we get the S0C4-11 when I had expected an S0C1. I 
> trust once I understand this, I'll be able to continue debugging the 
problem.

  The most likely explanation is that the target address of the BASSM
was not GETMAINed storage at the time of the abend (causing the
0C4-11 abend), but was subsequently GETMAINed and used before the dump 
was initiated or as part of the dump processing. 

Jim Mulder z/OS Diagnosis, Design, Development, Test, etc. IBM Corp. 
Poughkeepsie, NY


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN