You can't update a PDS/E from one Lpar and expect the updates to be seen from 
another Lpar unless you are sharing in at least a basic Sysplex. A mixed set of 
Monoplexs like mine need not apply. And if the update is in anyway 
bidirectional, you will experience a corrupted PDS/E

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of Paul Gilmartin
> Sent: Thursday, September 15, 2016 10:48 AM
> To: [email protected]
> Subject: Re: PDS/E Cobol
> 
> On Thu, 15 Sep 2016 10:26:53 -0700, Lizette Koehler  wrote:
> 
> >You can use normal utilities to copy a PDS/E member to another place.
> >
> >TRSMAIN,
> >TSO XMIT/RECEIVE
> >IEBCOPY Unload
> >
> May require parallel sysplex.  But no need to unload; can IEBCOPY from PDSE
> to PDSE.
> 
> >DFDSS Dump/RESTORE
> >
> >If you are using PDS/E Generations, there are some challenges with that.
> 
> -- gil
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to
> [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to