What kind of system symbols are you asking about?

The ones you code in IEASYMxx or the ones that come with the System, like 
SYSPLEX, SYSCLONE, date things?

I have not seen much documentation on monitoring any of the system symbols

And do not forget if you have scheduling software, like CA Workload Automation 
ESP, BMC Control-?, they may have their own ways of generating their own 
symbols.

And then there is JCL Symbols (EXPORT and SET function in JCL).

Is there a problem you are trying to solve? For instance, Identify any symbols 
defined in IEASYMxx that are no longer used?

There is also symbols in Dataset names set by DEF ... SYMBOLICRELATE.



Lizette

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Ravi Gaur
> Sent: Wednesday, October 05, 2016 7:41 AM
> To: [email protected]
> Subject: MVS System Symbol usage ??
> 
> is there a way via coding exit or from smf to know the usage of the system
> symbols ?? it's being asked due to the reason that before removing some of
> them it's required to be thoroughly verified if not being used....some ideas
> would be welcome...
> 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to