On Mon, 5 Dec 2016 08:24:12 -0500, Carmen Vitullo wrote: >mermber definition in both systems jes2parms are;
(snipped) You may be focusing unnecessarily on your JES2PARMS. Many parameters, including MASDEF cannot be changed with a warm start. The only way tho change them is with a cold start, or via command, e.g. $TMASDEF. -- Tom Marchant ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN