Thanks Jesse, I wondered about the late yesterday before I left, on my test LPAR there was another defunked system there, I tested the process of removing the system, I think I should have followed the same process in the prod mas I was defining from the MAS display currently, since I did back this out:
SDSF MAS DISPLAY SYSA LITJES2 26% SPOOL LINE 1-2 (2) COMMAND INPUT ===> SCROLL ===> PAGE PREFIX=OPERC* DEST=(ALL) OWNER=* SYSNAME= NP NAME Status SID PrevCkpt Hold ActHold Dormancy ActDorm Sync SYSA ACTIVE 1 0.27 40 40 (100,500) 229 SYSB DRAINED,P 2 0.00 0 0 (0,0) 0 SYSB was the old system I wanted to replace shifting left on the MAS display shows NAME ol Ind RSID SysName SYSA 00 NO SYSA SYSB 0 NO SYSC <- this is the system I want to add to the MAS, so I think I need to follow the doc more carefully, remove the system bu adding MEMBER(2),NAME= WARM start JES2, respond to the initialization message, then shut down JES2 update JES2PARMS with MEMBER(2),NAME=SYSC WARM start JES2, respond to the initialization message Can't see any other reason for jobs submit but will not run, it has to be a mismatch in the PARMS, or I'm not following the process correctly to add/replace a system into a MAS. Thanks again Jesse Carmen ----- Original Message ----- From: "Jesse 1 Robinson" <[email protected]> To: [email protected] Sent: Monday, December 5, 2016 4:17:52 PM Subject: Re: new JES2 MAS jobs will not run on member 2 Following this line of inquiry, get into SDSF and type MAS. There could be a discrepancy between the definition for the new member and its old gone-but-not-necessarily-forgotten ancestor. Replacing a member IIRC is a multistep process that involves first deleting the old guy, then defining the new guy. There could be conflicting attributes hanging around. . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-302-7535 Office [email protected] -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Tom Marchant Sent: Monday, December 05, 2016 10:10 AM To: [email protected] Subject: (External):Re: new JES2 MAS jobs will not run on member 2 On Mon, 5 Dec 2016 08:24:12 -0500, Carmen Vitullo wrote: >mermber definition in both systems jes2parms are; (snipped) You may be focusing unnecessarily on your JES2PARMS. Many parameters, including MASDEF cannot be changed with a warm start. The only way tho change them is with a cold start, or via command, e.g. $TMASDEF. -- Tom Marchant ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN