Elardus,

No I didn't need to use TOLerate.  I'm assuming you meant TOL(ENQF).  If I 
would need to use TOL(IOER) I have bigger problems.  :-)  And I just looked it 
up, it appears that TOL(ENQF) isn't even a viable option on a COPY FULL command.

Rex

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Elardus Engelbrecht
Sent: Tuesday, January 10, 2017 12:09 AM
To: [email protected]
Subject: Re: IPLing z/OS 2.2 from 1.13 for first time getting JES2 catastrophic 
error

Pommier, Rex wrote:

>I had the same thoughts over the weekend and messing with it this morning, I 
>discovered the problem.  I had neglected to use the ALLD and ALLE parameters 
>in my DFDSS job to copy the spool and checkpoint volumes.  So DFDSS dutifully 
>copied the pointers to "empty" datasets.  

Excellent! ALLEXCP and ALLDATA! Thats them. You need them to clone [all] your 
JES2 data.

Perhaps a documentation update should be placed in JES2 migration guide and 
Program Directory about this?

Oh, BTW, did you also need to use TOLERATE? Just curious.


>Guessing I'm not going to forget this one!

Neither me, I remember that I also burned my fingers badly during cloning of a 
system for testing out Y2K... 

;-)

Groete / Greetings
Elardus Engelbrecht

How many electrical engineers does it take to change a light bulb? We don't 
know yet, they're still waiting for a part.
How many programmers does it take to change a light bulb? None - it is a 
hardware problem.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN


The information contained in this message is confidential, protected from 
disclosure and may be legally privileged.  If the reader of this message is not 
the intended recipient or an employee or agent responsible for delivering this 
message to the intended recipient, you are hereby notified that any disclosure, 
distribution, copying, or any action taken or action omitted in reliance on it, 
is strictly prohibited and may be unlawful.  If you have received this 
communication in error, please notify us immediately by replying to this 
message and destroy the material in its entirety, whether in electronic or hard 
copy format.  Thank you.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to