Job TNCA1300 runs three times on the same LPAR with the same data and id.

Run 1 – production COBOL program, calls production assembler program, runs 
successfully.

Bring production COBOL program into a development PDS and compile program 
without changes.

Run 2- development program, calls production assembler program, fails with SOC4 
in assembler program.

Add these two lines of code to COBOL program to bypass header record on input 
dataset:

     IF WS-NA-RECORDS-READ EQUAL 1                                
        GO TO 1200-READ-MASTER.

Compile COBOL program with change. Compile output messages identical to first 
compile.

Run 3 – development COBOL program (changed), calls production assembler 
program, runs successfully.

Note: No overrides or changes to AMODE, RMODE or DATA during the test. Using 
the shops default compile and link settings.

Program moves from the FD to WORKING-STORAGE before the call to the assembler 
program for all “input” parameters.

I am missing something here; I do not see why this code would resolve the SOC4. 
Or has mentioned, missing something else… the unknown unknowns

----------------------------------------------------------------------