Rob, you're completely right, SYS.IEFUSI is a different *exitname* to SYSTSO.IEFUSI. That explains why I saw DYNX with only the default IEFUSI - I looked at the wrong statement. Now I see that DYNX shows me two lines: SYSTSO.IEFUSI 1 IEFUSITS YES YES 8E0A0EA8 0E0A0EA8 00000158 SYSTSO.IEFUSI 2 IEFUSI YES YES 86995410 00000000 00000000
(although I still don't understand why the second is showing me a MODEPA but no LoadPt or ModLen). Unfortunately: D PROG,EXIT,EN=SYSTSO.IEFUSI CSV461I 07.06.25 PROG,EXIT DISPLAY 778 EXIT MODULE STATE MODULE STATE MODULE STATE SYSTSO.IEFUSI IEFUSITS A IEFUSI A D PROG,EXIT,EN=SYSTSO.IEFUSI,DIAG CSV464I 07.11.47 PROG,EXIT DISPLAY 786 EXIT SYSTSO.IEFUSI MODULE STATE EPADDR LOADPT LENGTH JOBNAME PARAM IEFUSITS A 8E0A0EA8 0E0A0EA8 00000158 * IEFUSI A 86995410 00000000 00000000 * Why are the two displays different (other than the obvious more information from the diag parm)? I expected the one without DIAG to show both exits, too! Barbara ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN