I was kinda blind. The Exit command without DIAG shows both exits, it just doesn't show them vertically.
Why are the LoadPt and ModLen for the IPL-loaded Exits not shown in either DYNX or the DIAG output? Barbara >you're completely right, SYS.IEFUSI is a different *exitname* to >SYSTSO.IEFUSI. That explains why I saw DYNX with only the default IEFUSI - I >looked at the wrong statement. Now I see that DYNX shows me two lines: > SYSTSO.IEFUSI 1 IEFUSITS YES YES 8E0A0EA8 0E0A0EA8 00000158 > SYSTSO.IEFUSI 2 IEFUSI YES YES 86995410 00000000 00000000 > >(although I still don't understand why the second is showing me a MODEPA but >no LoadPt or ModLen). > >Unfortunately: > >D PROG,EXIT,EN=SYSTSO.IEFUSI >CSV461I 07.06.25 PROG,EXIT DISPLAY 778 >EXIT MODULE STATE MODULE STATE MODULE STATE >SYSTSO.IEFUSI IEFUSITS A IEFUSI A > >D PROG,EXIT,EN=SYSTSO.IEFUSI,DIAG >CSV464I 07.11.47 PROG,EXIT DISPLAY 786 >EXIT SYSTSO.IEFUSI >MODULE STATE EPADDR LOADPT LENGTH JOBNAME PARAM >IEFUSITS A 8E0A0EA8 0E0A0EA8 00000158 * >IEFUSI A 86995410 00000000 00000000 * > >Why are the two displays different (other than the obvious more information >from the diag parm)? I expected the one without DIAG to show both exits, too! > >Barbara > >---------------------------------------------------------------------- >For IBM-MAIN subscribe / signoff / archive access instructions, >send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN