>Since we do not use APPC, are type "AO" address spaces all UNIX process >running in BPXAS initiator address spaces?
It appears so. I recently implemented OPERCMDS security for START/STOP commands, and when a SAS User tries to kill his hanging process/thread/whatever into USS, the CANCEL profile actually asked for by z/OS is MVS.CANCEL.ATX.*. The ATX part according to the documentation means that we're dealing with an APPC address space of some sort which I found very curious. Barbara ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN