I know it's improper and doesn't work and shouldn't have happened. But it did.
Important jobs now get:
IEC036I 002-A4,IGC0005E,
And
IEA995I SYMPTOM DUMP OUTPUT
SYSTEM COMPLETION CODE=0F4 REASON CODE=00000024
TIME=12.02.23 SEQ=00630 CPU=0000 ASID=002A
PSW AT TIME OF ERROR 075C0001 848D7DAA ILC 2 INTC 0D
NO ACTIVE MODULE FOUND - PRIMARY NOT EQUAL TO HOME
NAME=UNKNOWN
DATA AT PSW 048D7DA4 - 58F0D818 0A0DD707 DB00DB00
AR/GR 0: 008FF6C8/00000000_141AA085 1: 00000000/00000000_040F4000
2: 00000001/00000000_00FDEB40 3: 00000000/00000000_7F0D1808
4: 00000001/00000050_00000003 5: 00000002/00000000_00FD7940
6: 00000001/00000000_00FD79B0 7: 00000000/00000000_7F0D17B8
8: 00000000/00000000_7F0D208F 9: 00000000/00000000_00000000
A: 00000000/00000000_026A3148 B: 00000000/00000000_7F0CC0C0
C: 00000000/00000000_048D8A28 D: 00000000/00000000_7F0D1090
E: 00000000/00000000_848D7D9A F: 00000000/00000000_00000024
END OF SYMPTOM DUMP
When accessing this PDS/E from Lpars that aren't the one that updated it.
Short of IPL, can I fix this? z/OS 2.1
Dave Gibney
Information Technology Services
Washington State University
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN