Two thoughts.

1)  Try using IEBPDSE on the file.

2)  Can you copy it to another PDSE?

Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Gibney, Dave
> Sent: Monday, February 27, 2017 1:24 PM
> To: [email protected]
> Subject: PDS/E improperly shared and updated between monoplexes :(
> 
> I know it's improper and doesn't work and shouldn't have happened. But it did.
> 
> Important jobs now get:
> IEC036I 002-A4,IGC0005E,
> And
> IEA995I SYMPTOM DUMP OUTPUT
> SYSTEM COMPLETION CODE=0F4  REASON CODE=00000024
>  TIME=12.02.23  SEQ=00630  CPU=0000  ASID=002A
>  PSW AT TIME OF ERROR  075C0001   848D7DAA  ILC 2  INTC 0D
>    NO ACTIVE MODULE FOUND - PRIMARY NOT EQUAL TO HOME
>    NAME=UNKNOWN
>    DATA AT PSW  048D7DA4 - 58F0D818  0A0DD707  DB00DB00
>    AR/GR 0: 008FF6C8/00000000_141AA085   1: 00000000/00000000_040F4000
>          2: 00000001/00000000_00FDEB40   3: 00000000/00000000_7F0D1808
>          4: 00000001/00000050_00000003   5: 00000002/00000000_00FD7940
>          6: 00000001/00000000_00FD79B0   7: 00000000/00000000_7F0D17B8
>          8: 00000000/00000000_7F0D208F   9: 00000000/00000000_00000000
>          A: 00000000/00000000_026A3148   B: 00000000/00000000_7F0CC0C0
>          C: 00000000/00000000_048D8A28   D: 00000000/00000000_7F0D1090
>          E: 00000000/00000000_848D7D9A   F: 00000000/00000000_00000024
> END OF SYMPTOM DUMP
> 
> When accessing this PDS/E from Lpars that aren't the one that updated it.
> 
> Short of IPL, can I fix this? z/OS 2.1
> 
> Dave Gibney
> Information Technology Services
> Washington State University
> 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to