Two thoughts. 1) Try using IEBPDSE on the file.
2) Can you copy it to another PDSE? Lizette > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Gibney, Dave > Sent: Monday, February 27, 2017 1:24 PM > To: [email protected] > Subject: PDS/E improperly shared and updated between monoplexes :( > > I know it's improper and doesn't work and shouldn't have happened. But it did. > > Important jobs now get: > IEC036I 002-A4,IGC0005E, > And > IEA995I SYMPTOM DUMP OUTPUT > SYSTEM COMPLETION CODE=0F4 REASON CODE=00000024 > TIME=12.02.23 SEQ=00630 CPU=0000 ASID=002A > PSW AT TIME OF ERROR 075C0001 848D7DAA ILC 2 INTC 0D > NO ACTIVE MODULE FOUND - PRIMARY NOT EQUAL TO HOME > NAME=UNKNOWN > DATA AT PSW 048D7DA4 - 58F0D818 0A0DD707 DB00DB00 > AR/GR 0: 008FF6C8/00000000_141AA085 1: 00000000/00000000_040F4000 > 2: 00000001/00000000_00FDEB40 3: 00000000/00000000_7F0D1808 > 4: 00000001/00000050_00000003 5: 00000002/00000000_00FD7940 > 6: 00000001/00000000_00FD79B0 7: 00000000/00000000_7F0D17B8 > 8: 00000000/00000000_7F0D208F 9: 00000000/00000000_00000000 > A: 00000000/00000000_026A3148 B: 00000000/00000000_7F0CC0C0 > C: 00000000/00000000_048D8A28 D: 00000000/00000000_7F0D1090 > E: 00000000/00000000_848D7D9A F: 00000000/00000000_00000024 > END OF SYMPTOM DUMP > > When accessing this PDS/E from Lpars that aren't the one that updated it. > > Short of IPL, can I fix this? z/OS 2.1 > > Dave Gibney > Information Technology Services > Washington State University > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN