I use LPAR, Release and RSU level qualifiers for the OMVS files I'm running out 
of.
SMP/E target is never referenced for operational components.

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of Allan Staller
> Sent: Friday, March 10, 2017 12:59 PM
> To: [email protected]
> Subject: Re: CATCONVERT for os migration
> 
> If you need coexistence, you are out of luck. You will have to create copies 
> of
> the files with new names.
> If you do not need coexistence, just unmount/remount the files.
> 
> IDCAMS allows DEFINE RECATALOG to be specified for files w/HLQ of SYS1 or
> PAGE (IIRC). OMVS is not allowed.
> DEFINE RECATALOG allows the same physical dataset to be in 2 separate
> catalogs concurrently.
> 
> Check the fine manual, the may have been an update I missed.
> 
> In the past I have included the volser in the file name as a means of making 
> it
> unique. E.g. OMVS.ROOT.volser.ZFS
> 
> HTH,
> 
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of David Larry
> Sent: Friday, March 10, 2017 2:40 PM
> To: [email protected]
> Subject: Re: CATCONVERT for os migration
> 
> Hi Allan
> 
> the Hilvl is OMVS, which is also a hilvl in my new 2.2 master catalog as well.
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to
> [email protected] with the message: INFO IBM-MAIN
> 
> 
> ::DISCLAIMER::
> --------------------------------------------------------------------------------------------------------
> --------------------------------------------
> 
> The contents of this e-mail and any attachment(s) are confidential and
> intended for the named recipient(s) only.
> E-mail transmission is not guaranteed to be secure or error-free as
> information could be intercepted, corrupted, lost, destroyed, arrive late or
> incomplete, or may contain viruses in transmission. The e mail and its
> contents (with or without referred errors) shall therefore not attach any
> liability on the originator or HCL or its affiliates.
> Views or opinions, if any, presented in this email are solely those of the
> author and may not necessarily reflect the views or opinions of HCL or its
> affiliates. Any form of reproduction, dissemination, copying, disclosure,
> modification, distribution and / or publication of this message without the
> prior written consent of authorized representative of HCL is strictly
> prohibited. If you have received this email in error please delete it and 
> notify
> the sender immediately.
> Before opening any email and/or attachments, please check them for viruses
> and other defects.
> 
> --------------------------------------------------------------------------------------------------------
> --------------------------------------------
> 
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to
> [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to