Has this always been so. Sometime ago (1.7, 1.9) I had ACCEPT fail because I 
had compressed and moved members into lower sequenced SMPPTSn
At least I think I remember this. I've just always added another SMPPTSz ever 
since.

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of Jesse 1 Robinson
> Sent: Thursday, March 16, 2017 3:45 PM
> To: [email protected]
> Subject: Re: Can SMPPTS datasets be consolidated?
> 
> SMP/E does not keep a permanent record of which PTS holds a particular
> sysmod. On every query, the concatenated PTS libraries are searched. If the
> sysmod is found, the particular library is named, otherwise 'not found'. This
> allows you to freely manipulate the libraries and their content. Worst case,
> after consolidating PTS libraries, exit and re-enter the SMP/E dialog.
> 
> .
> .
> J.O.Skip Robinson
> Southern California Edison Company
> Electric Dragon Team Paddler
> SHARE MVS Program Co-Manager
> 323-715-0595 Mobile
> 626-543-6132 Office ⇐=== NEW
> [email protected]
> 
> 
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of Gibney, Dave
> Sent: Thursday, March 16, 2017 1:37 PM
> To: [email protected]
> Subject: (External):Re: Can SMPPTS datasets be consolidated?
> 
> I am not sure the process. I'd advise adding more secondary PPTS datasets.
> SMP/E remembers which PPTS a given PTF is in.
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of Allan Staller
> > Sent: Thursday, March 16, 2017 1:34 PM
> > To: [email protected]
> > Subject: Re: Can SMPPTS datasets be consolidated?
> >
> > YES-----Original Message-----From: IBM Mainframe Discussion List
> > [mailto:[email protected]] On Behalf Of Herring, BobbySent:
> > Thursday, March 16, 2017 3:30 PMTo: IBM-
> [email protected]:
> > Can SMPPTS datasets be consolidated?I am in the process of receiving a
> > large RSU maintenance order. I have filled up three SMPPTS datasets
> > that were not defined large enough.Can these be merged and
> > consolidated into one or two much larger datasets?Bobby HerringTexas
> > Farm Bureau
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to