You can concatenate them or just build a new SMPPTS and change the name in the DDEF
https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.2.0/com.ibm.zos.v2r2.gim2000/dspts1.htm -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Dan Little Sent: Thursday, March 16, 2017 7:58 PM To: [email protected] Subject: Re: Can SMPPTS datasets be consolidated? I thought the SMMPTSx DDDEF was recorded in the global zone and that consolidating could not easily be done. Dan On Thu, Mar 16, 2017 at 19:26 Gibney, Dave <[email protected]> wrote: > Has this always been so. Sometime ago (1.7, 1.9) I had ACCEPT fail > because I had compressed and moved members into lower sequenced > SMPPTSn At least I think I remember this. I've just always added > another SMPPTSz ever since. > > > -----Original Message----- > > From: IBM Mainframe Discussion List > > [mailto:[email protected]] On Behalf Of Jesse 1 Robinson > > Sent: Thursday, March 16, 2017 3:45 PM > > To: [email protected] > > Subject: Re: Can SMPPTS datasets be consolidated? > > > > SMP/E does not keep a permanent record of which PTS holds a > > particular sysmod. On every query, the concatenated PTS libraries > > are searched. If > the > > sysmod is found, the particular library is named, otherwise 'not found'. > This > > allows you to freely manipulate the libraries and their content. > > Worst > case, > > after consolidating PTS libraries, exit and re-enter the SMP/E dialog. > > > > . > > . > > J.O.Skip Robinson > > Southern California Edison Company > > Electric Dragon Team Paddler > > SHARE MVS Program Co-Manager > > 323-715-0595 Mobile > > 626-543-6132 Office ⇐=== NEW > > [email protected] > > > > > > -----Original Message----- > > From: IBM Mainframe Discussion List > > [mailto:[email protected]] On Behalf Of Gibney, Dave > > Sent: Thursday, March 16, 2017 1:37 PM > > To: [email protected] > > Subject: (External):Re: Can SMPPTS datasets be consolidated? > > > > I am not sure the process. I'd advise adding more secondary PPTS > datasets. > > SMP/E remembers which PPTS a given PTF is in. > > > > > -----Original Message----- > > > From: IBM Mainframe Discussion List > > > [mailto:[email protected]] On Behalf Of Allan Staller > > > Sent: Thursday, March 16, 2017 1:34 PM > > > To: [email protected] > > > Subject: Re: Can SMPPTS datasets be consolidated? > > > > > > YES-----Original Message-----From: IBM Mainframe Discussion List > > > [mailto:[email protected]] On Behalf Of Herring, BobbySent: > > > Thursday, March 16, 2017 3:30 PMTo: IBM- > > [email protected]: > > > Can SMPPTS datasets be consolidated?I am in the process of > > > receiving a large RSU maintenance order. I have filled up three > > > SMPPTS datasets that were not defined large enough.Can these be > > > merged and consolidated into one or two much larger datasets?Bobby > > > HerringTexas Farm Bureau > > > > -------------------------------------------------------------------- > > -- For IBM-MAIN subscribe / signoff / archive access instructions, > > send email to [email protected] with the message: INFO > > IBM-MAIN > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN