AFAIK, There is one set per sysplex, just like all the other CF control datasets. We've been setup that for 10 years, and no problems. Now, you can define separate sets of RLS buffers in the CF to separate Catalogs, from application VSAM datasets.
_________________________________________________________________ Dave Jousma Manager Mainframe Engineering, Assistant Vice President [email protected] 1830 East Paris, Grand Rapids, MI 49546 MD RSCB2H p 616.653.8429 f 616.653.2717 -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Jorge Garcia Sent: Wednesday, April 26, 2017 6:35 AM To: [email protected] Subject: Set up SHCDS datasets in RLS enviroment Hi all, We're going to set up RSV enviroment in our test sysplex to migrate to RLS catalogs. We need to define SHCDS SMS datasets and we have some questions. This is our actual test sysplex enviroment. Paralel syplex 1 CF 2 systems 2 master cat 2 RACF 2 DFSMS enviroment Our questions are: Do we need to share SHCDS between both systems to set up RLS enviroment? or Can we define SHCDS separately in both systems (different SMS configuration)? Regards Jorge Garcia Juanino Coordinador sistemas z/OS ACTP – DIAC – Operación y Soporte EMEA MAPFRE Avenida del Talgo 100-103 – 3ª Planta CP 28023 Madrid Tel. 91 581 27 34, Movil 618333559 [email protected] ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN This e-mail transmission contains information that is confidential and may be privileged. It is intended only for the addressee(s) named above. If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. If you are not the intended recipient, any disclosure, copying, distribution or use of the contents of this information is prohibited. Please reply to the message immediately by informing the sender that the message was misdirected. After replying, please erase it from your computer system. Your assistance in correcting this error is appreciated. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN