That APAR may look enticing, but it's pretty unlikely. Some data/time field in Unicode turned all zero in late 2015. Anyone who IPLed after that moment in time would get Unicode initialization failure. I doubt that OP has avoided IPL all this time unless it's a very infrequently used LPAR.
. . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW [email protected] -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Gord Tomlin Sent: Tuesday, June 06, 2017 1:10 PM To: [email protected] Subject: (External):Re: CSSMTP Startup Failure On 2017-06-06 14:58, Vinson Lee wrote: > We're still on z/OS 1.13 and just IPL'ed. The CSSMTP started task won't come > up and we're getting this: > > EZD1807I CSSMTP ERROR IN INITIALIZATION : CONFIGURATION FILE ERRORS > > We also see this in the log: > > CSSMTP INFO :001:mlCfgOpenSocket:IPv4 socket successfully open/closed > CSSMTP DEBUG :001:mlIconvTest:CUNLINFO error 8:11 CSSMTP ERROR > :001:mlIconvTest:Tests for codepage 'IBM-1047' failed. Unicode > services are not available (2) CSSMTP ERROR :001:mlIconvTest:LE > function CUNLINFO failed: EDC5262I An iconv() function encountered an > unexpected error while using Unicode Services. (errno2=0x0000050A) CSSMTP > ERROR :001:mlCfgOperCmd:'IBM-1047' is not a valid code page for > 'CSSMTP_CODEPAGE_CONFIG' > > > Don't recall having to do anything specific for Unicode and my > research shows the IBM-1047 codepage should be available by default. > A display shows this > > D UNI,ALL > CUN3000I 11.47.46 UNI DISPLAY 242 > ENVIRONMENT: CREATED 06/06/2017 AT 11.06.21 > MODIFIED 06/06/2017 AT 11.14.12 > IMAGE CREATED --/--/---- AT --.--.-- > SERVICE: CHARACTER CASE NORMALIZATION COLLATION > STRINGPREP BIDI CONVERSION INF > STORAGE: ACTIVE 89 PAGES > FIXED 0 PAGES > LIMIT 524287 PAGES > CASECONV: DISABLED > CASE VER: NONE > NORMALIZE: DISABLED > NORM VER: NONE > COLLATE: DISABLED > COLL RULES: NONE > STRPROFILES: NONE > CONVERSION: 01200(13488)-00037-E 01208-00037-E > 00037-00367-E 00037-01208-R > 00367-00037-E 00037-01200(13488)-R > 00819-01047-L 00819-01047-R > 01047-00819-L 01047-00819-R > 01047-00850-R 01047-00850-C > > > Anyone come across this problem before? Any suggestions on what to do? > > Thanks in advance. > > Vince > This looks suspiciously like the symptoms of OA48941: http://www-01.ibm.com/support/docview.wss?uid=isg1OA48941 You might want to see whether the associated PTF is applied. -- Regards, Gord Tomlin Action Software International (a division of Mazda Computer Corporation) Tel: (905) 470-7113, Fax: (905) 470-6507 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN