It should not be possible to get a 052 abend from VSMLOC, unless some rogue code on your system has messed with the System Function Table so that the wrong PC number is being issued, or some rogue code on your system has messes with the Entry Table Entry for the VSMLOC PC so that something other than the VSMLOC service routine is being invoked by the VSMLOC PC.
Jim Mulder z/OS Diagnosis, Design, Development, Test IBM Corp. Poughkeepsie NY > From: Joe Reichman <reichman...@gmail.com> > To: IBM-MAIN@LISTSERV.UA.EDU > Date: 08/07/2017 09:24 PM > Subject: Various 052 abends with LINKAGE=SYSTEM calls in SRB > Sent by: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> > I am getting intermittent abends with a couple of macros that use > linkage=system in a SRB > The first is with AXSET macro > > LA R2,1 Give us the > AXSET AX=(R2) Power > XR R8,8 Clear r8 > ICM R8,B'0011',NOW.HASID Get Server Asid > SSAR R8 Set secondary Asid > > The reason code for the AXSET is 0101 > > The Abends happens (sometimes) after the PC 0(14) call in the AXSET > > To other is in the VSMLOC macro again after the PC 0(14) The reason code in > the VSMLOC is 0103 > > From my understanding there is no restriction using LINKAGE=SYSTEM in a SRB ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN