I misspoke in my original post. The three-qualifier data set names were our own choice to preserve the ServerPac qualifier but still fit into our naming standards. It was not a whimsical choice. We have 7 SAF-plexes to maintain. Introducing even one new HLQ means a lot of work to make all seven work for us. So at first we appended SYS1 to the front, making a three qualifier name with no SAF prep work required. Eventually we decided that the ServerPac HLQ was pointless and just removed it in subsequent releases. All data sets are now SYS1.xxxxxxxx with the necessarily unique llq that SMPE knows.
So my real question is whether you set up and maintain the ServerPac HLQs or just drop them as we do? As I said earlier, I don't see any benefit worth the trouble they are to manage. . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW [email protected] -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Gibney, Dave Sent: Monday, September 25, 2017 2:34 PM To: [email protected] Subject: (External):Re: SYS1 names (was SYS3 datasets) My SererPac(s) have always come as TCPIP.llq, CEE.llq, ASM.llq etc. and I've kept them. We did have a collision once before BMC bought IOA. IBM won ... > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Jesse 1 Robinson > Sent: Monday, September 25, 2017 2:23 PM > To: [email protected] > Subject: SYS1 names (was SYS3 datasets) > > ServerPac supplies a number of default names with three qualifiers > such as SYS1.TCPIP.llq. We routinely eliminate any middle qualifier as > being both redundant and confusing. > > 1. SMPE knows data sets by llq. SMPE cannot manage hlq.mlq1.llq and > hlq.mlq2.llq concurrently. JCLIN does not know from anything other than llq. > 2. Who can remember which data set groups have an mlq and which do not? > > Does anyone attempt to carry these default names forward to production? > > . > . > J.O.Skip Robinson > Southern California Edison Company > Electric Dragon Team Paddler > SHARE MVS Program Co-Manager > 323-715-0595 Mobile > 626-543-6132 Office ⇐=== NEW > [email protected] > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Gibney, Dave > Sent: Monday, September 25, 2017 1:00 PM > To: [email protected] > Subject: (External):Re: SYS3 datasets > > To my knowledge, we've never had any SYS3 datasets. Kinda makes me > cringe :) There's still a couple SYS2 from very old habits, but in > general, we stick with what IBM provides for IBM and usually what the > ISV suggests for other. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN