Correct; with LNKAUTH=APFTAB that particular risk goes away. 

--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3

________________________________________
From: IBM Mainframe Discussion List <IBM-MAIN@listserv.ua.edu> on behalf of Tom 
Marchant <0000000a2a8c2020-dmarc-requ...@listserv.ua.edu>
Sent: Tuesday, December 19, 2017 2:59 PM
To: IBM-MAIN@listserv.ua.edu
Subject: Re: Cobol upgrade 6.2 linklist

On Tue, 19 Dec 2017 12:12:07 -0700, Lizette Koehler wrote:

>Once a dataset is in the linkst - depending on how it is controlled - someone 
>could put other code in there that is not system friendly.
>
>So I have dataset, MYHLQ.USER.LOADLIB in the linklist.
>
>Now it is apf authorized.

Maybe yes, maybe no.

See LNKAUTH=APFTAB

--
Tom Marchant

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to