Did you request pre-req maint? (the prior 90 days worth of pre-reqs will be included with the order). This is a check-off box when you specify the PTFs requested.
-----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Carmen Vitullo Sent: Wednesday, December 20, 2017 8:15 AM To: [email protected] Subject: Re: Cobol upgrade 6.2 linklist ok, so along the lines of COBOL 6.2 we're getting prepared to install and test, we found an LE PTF required for 6.2, so on to IBMLINK and ordered all pre reqs PE fixes, superseding, superseded....PTF's for this PTF, for a while now I've been getting nothing but the PTF I order, so during my apply, guess what 'CONDITIONAL REQUISITE SYSMOD UI49212 WAS MISSING.' so has the order process changed or is SRD not working as it use to? I remember a day (years ago), I'd order a PTF and get 10 maybe 20 requisite PTF's not anymore, so am I not selecting all the correct options? Carmen Vitullo ----- Original Message ----- From: "Bruce Hewson" <[email protected]> To: [email protected] Sent: Tuesday, December 19, 2017 9:43:28 PM Subject: Re: Cobol upgrade 6.2 linklist Hi, So Production Control will manage the promotion of modules to the linklisted datasets. Since it is a PDSE dataset it will always have an active connection and so will not be able to perform automatic compression. Thus it will get full. The same Production Control group would be responsible for promotion of Production JCL, and therefore can AUDIT such JCl for valid JOBLIB/STEPLIB specifications. Therefore the AUDITORs recommendations regarding misuse of STEPLIB must be considered unfounded. Promotion of JCL containing "bad" STEPLIB datasets, or promotion of "bad" program modules, follows the same Production Control validation/auditing processes, and would therefore be just as susceptible to misuse no matter which process was followed. Use of JCL check products can assist validation of STEPLIB dataset specifications. The Auditor's basically "cried wolf". Regards Bruce ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ::DISCLAIMER:: ---------------------------------------------------------------------------------------------------------------------------------------------------- The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. ---------------------------------------------------------------------------------------------------------------------------------------------------- ::DISCLAIMER:: ---------------------------------------------------------------------------------------------------------------------------------------------------- The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. ---------------------------------------------------------------------------------------------------------------------------------------------------- ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN