To disable DYNALLOC would be to cause MGMT to delete you job plain and simple

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of CM Poncelet
Sent: Wednesday, December 20, 2017 7:25 PM
To: [email protected]
Subject: Re: Disable DYNALLOC?

SVC 99 (aka macro DYNALLOC) allows doing much more than dataset (de)allocations 
via its TUP list parms.
 
So yes - it should always remain available for use in systems programs, 
irrespective of its being hypothetically "harmful" in production jobs (whatever 
they are).
 
My ha'penny.
 
Chris Poncelet (retired sysprog consultant)
 


On 20/12/2017 22:38, Paul Gilmartin wrote:
> >From a recent thread (rant?) in ASSEMBLER-LIST:
>
>     ... Do you stand by "SVC 99 for good measure"? Generally, products
>     do not implement it for good reason. Irrelevant in CICS and IMS. 
>     In batch, it bypasses job scheduler, job restart, violates  production
>     control requirements, bypasses JES3 resource management 
>     and potentially poses a production security risk. TSO has the 
>     alloc command which can easily be used in clists. It exists 
>     because of  MVS UNIX.  ...
>
> Disregard the anachronism in the last sentence.  If, hypothetically, 
> DYNALLOC except by initiator is so harmful as to be prohibited in 
> production jobs, is there any way to do so?  If it were possible, what 
> would be the collateral damage?  What fraction of production jobs 
> would work, unmodified, without using DYNALLOC?
>
> Are code reviews a better technique?  Other (specify)?
>
> -- gil
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send 
> email to [email protected] with the message: INFO IBM-MAIN .
>


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to