On Thu, 8 Mar 2018 13:32:35 -0600, Tom Marchant wrote: >I'm not familiar with that service, but it is very likely that the doc >is correct. The fact that the service requires a standard 18-word >save area is a clue.
When I sent the above reply, I hadn't noticed that the CSRL16J service is documented in two places with different information. The Assembler Services Reference specifies a requirement to pass a standard 18-word save area. The MVS callable Services for High Level Languages manual has different information. -- Tom Marchant ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN