You are referring to the SDWA right 


> On Mar 22, 2018, at 7:41 AM, Binyamin Dissen <[email protected]> 
> wrote:
> 
> Get the linkage stack entry from the dump.
> 
> Then get the R1 area using the linkage stack entry.
> 
> Also display the R2 area.
> 
> On Wed, 21 Mar 2018 21:54:29 -0400 Joe Reichman <[email protected]> wrote:
> 
> :>.hi
> :>I am getting an abend on xmem post I’ll post the macro
> :>
> :>        POST  (R4),                                                        X
> :>              (R7),                                                         
>     X
> :>              ASCB=(R2),                                                  X
> :>              ECBKEY=0,                                                  X
> :>              ERRET=ISSMES,                                          X
> :>              LINKAGE=SYSTEM,                                      X
> :>              MF=(E,S_DUMP.PSTDSECT)                                   
> :>
> :>I am stepping thru this under testauth and up unitl PC instruction
> :>Of the post everything is okay 
> :>I have checked the paramters 4 points to a ECB in CSA
> :>R2 points to the right ASCB 
> :>I display both from storage in TASID
> :>The ECB has the 80 bit on followed by the RB
> :>The ASCB at offset x’24’ has the right asid     
> :>I then make a breakpoint at the instruction after the post pc
> :>And my estae recovery routine 
> :>Execution goes to the recovery routine
> :>List below is the SDWA
> :>The abend code is 460 which isn’t documented
> :>The SDWANAME is zeros because I am running in supervisor state
> :>However the SDWAMODN is Nucleus
> :>And SDWACSCT points to  csect IEAVESLK
> :>
> :>Any suggestion how to further debug this would be appreciated
> :>thanks   
> :>   L 1R? L(255) M(2) XC                                                     
> :>                                                     
> :> 008B08D0.  00000000 84602000 0004000D 00000000  *....d-..........*  0000
> :>                       FF040061 00000000 84000000 84073000  
> *.../....d...d...*      
> :> 008B08F0.  9EC6963C 9EC6952C 00000038 00000BE0  *.Fo..Fn.........*      
> :>                     1E85B734 029AE580 017559B0 8002B3E0  
> *.e....V.........*      
> :> 008B0910.  00000000 00FB7880 00000000 00000000  *................*      
> :>                     8175387C 0000000C 008B4198 00000000  
> *[email protected]....*      
> :> 008B0930.  00000000 00000000 040C1000 8128B24E  *............a..+*      
> :>                      0002000D 7F485400 070C1000 9EC6952C  
> *...."........Fn.*      
> :> 008B0950.  00020061 7F485400 8002B3E0 9EC7BAB4  *.../"........G..*      
> :>                      00FB7880 1EC693D0 1E85B734 1EC6F5EC  
> *.....Fl..e...F5.*      
> :> 008B0970.  1EC6F5EC 0002B3E0 1EC6F614 00000098  *.F5......F6....q*      
> :>                     1EC7B072 00F99280 1EC7B000 1EC7BA6A  
> *.G...9k..G...G..*      
> :> 008B0990.  0000030E 1EC6963C E6000730 00000000  *.....Fo.W.......*      
> :>                     00000000 00000000 00000000 00000000  
> *................*      
> :> 008B09B0.  00000000 00000000 04020001 00001000  *................*      
> :>                     00000000 008B0A60 00000000 000000    *.......-....... 
> *      
> :> 008B09CF.  00000000 00000000 00000000 00000000  *................*      
> :>                     00000000 00000000 00000000 00000000  
> *................*      
> :> 008B09EF.  00003800 0040D5E4 C3D3C5E4 E2C9C5C1  *..... NUCLEUSIEA*      
> :>                    E5C5E2D3 D2000000 00000000 00008B0A  *VESLK...........* 
>      
> :>
> :>----------------------------------------------------------------------
> :>For IBM-MAIN subscribe / signoff / archive access instructions,
> :>send email to [email protected] with the message: INFO IBM-MAIN
> 
> --
> Binyamin Dissen <[email protected]>
> http://www.dissensoftware.com
> 
> Director, Dissen Software, Bar & Grill - Israel
> 
> 
> Should you use the mailblocks package and expect a response from me,
> you should preauthorize the dissensoftware.com domain.
> 
> I very rarely bother responding to challenge/response systems,
> especially those from irresponsible companies.
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to