feels like a friday :( sorry I intended to respond to this POST
: z/OS 1.13 maintenance concern. May 2, 2018 7:56 AM
Carmen Vitullo
----- Original Message -----
From: "Carmen Vitullo" <[email protected]>
To: [email protected]
Sent: Wednesday, May 2, 2018 7:54:01 AM
Subject: Re: [EXTERNAL] Re: HLQ change of SMP/E files
In a case like this I'd like to use the fixcat's like
FIXCAT(IBM.Coexistence.z/OS.V2R1 FIXCAT + (IBM.Coexistence.z/OS.V2R2) that are
available now, it may produce a lot of required PTF's but SHOPZ + fixcats for
required service for 2.1 and 2.2 ?
or choose the upgrade option in the PSP buckets ?
Carmen Vitullo
----- Original Message -----
From: "Kurt Quackenbush" <[email protected]>
To: [email protected]
Sent: Wednesday, May 2, 2018 7:41:07 AM
Subject: Re: [EXTERNAL] Re: HLQ change of SMP/E files
On 5/1/2018 9:53 AM, Sankaranarayanan, Vignesh wrote:
> Ooh... almost forgot the other question - is there a way to test run
> this, equivalent of ADRDSSU's TYPRUN=NORUN?
No, no CHECK operand on ZONEEDIT. Frankly its a pretty safe operation,
but if you're concerned then make a copy of your CSI data set(s) that
contain the target and dlib zones and try it out on the copy first.
Kurt Quackenbush -- IBM, SMP/E Development
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN