That configuration is perfectly valid. You are merely missing some(but not all) 
 redundancy and recovery options.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of R.S.
Sent: Monday, July 9, 2018 9:20 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Sysplex between two hardware

W dniu 2018-07-09 o 15:41, Mark A. Brooks pisze:
> The essence of the matter is to ensure that the selected configuration meets 
> the availability objectives of the business services supported by the 
> sysplex.  One must consider the service restoration objectives for the 
> business services in light of the potential failures that can occur for a 
> potential choice of configuration.  There are many possibilities and 
> different installations will of course make different choices based on their 
> own business objectives.  Choices of standalone CF, or structure duplexing, 
> and the like are really all talking about different ways of solving the 
> "failure isolation" issue (wherein we might be concerned about the time to 
> restore the business service if we simultaneously lose the data in the CF 
> along with the system that produced that data).  Each choice has its own 
> advantages and disadvantages; choose the one that's right for you.
> --Mark Brooks
> --z/OS Sysplex Development
>

However "option c", that means we don't have standalone CF and we do not duplex 
CF structures is not proper one, is it?

Regards
--
Radoslaw Skorupka
Lodz, Poland




======================================================================


        --
 Treść tej wiadomości może zawierać informacje prawnie chronione Banku 
przeznaczone wyłącznie do użytku służbowego adresata. Odbiorcą może być jedynie 
jej adresat z wyłączeniem dostępu osób trzecich. Jeżeli nie jesteś adresatem 
niniejszej wiadomości lub pracownikiem upoważnionym do jej przekazania 
adresatowi, informujemy, że jej rozpowszechnianie, kopiowanie, rozprowadzanie 
lub inne działanie o podobnym charakterze jest prawnie zabronione i może być 
karalne. Jeżeli otrzymałeś tę wiadomość omyłkowo, prosimy niezwłocznie 
zawiadomić nadawcę wysyłając odpowiedź oraz trwale usunąć tę wiadomość 
włączając w to wszelkie jej kopie wydrukowane lub zapisane na dysku.

 This e-mail may contain legally privileged information of the Bank and is 
intended solely for business use of the addressee. This e-mail may only be 
received by the addressee and may not be disclosed to any third parties. If you 
are not the intended addressee of this e-mail or the employee authorized to 
forward it to the addressee, be advised that any dissemination, copying, 
distribution or any other similar activity is legally prohibited and may be 
punishable. If you received this e-mail by mistake please advise the sender 
immediately by using the reply facility in your e-mail software and delete 
permanently this e-mail including any copies of it either printed or saved to 
hard drive.

 mBank S.A. z siedzibą w Warszawie, ul. Senatorska 18, 00-950 Warszawa, 
https://apac01.safelinks.protection.outlook.com/?url=www.mBank.pl&data=02%7C01%7Callan.staller%40HCL.COM%7C10622a536f78423874c708d5e5a72f4d%7C189de737c93a4f5a8b686f4ca9941912%7C0%7C1%7C636667428590770229&sdata=eg%2FISBQY4%2BT0T%2BRPr%2FPulpGdLql5wRKMACmRqT4VxsQ%3D&reserved=0,
 e-mail: kont...@mbank.plsąd Rejonowy dla m. st. Warszawy XII Wydział 
Gospodarczy Krajowego Rejestru Sądowego, nr rejestru przedsiębiorców KRS 
0000025237, NIP: 526-021-50-88. Według stanu na dzień 01.01.2018 r. kapitał 
zakładowy mBanku S.A. (w całości wpłacony) wynosi 169.248.488 złotych.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to